Description
Features
- CAT II 700 V / CAT IV 600 V
- AC true RMS
- auto/manual range function
- auto power off function (15 minutes)
- data hold function
- relative measurement function
- display the correct socket sign
- low battery display function
- including: rechargeable battery, USB charger, test leads and carrying case
- size: 190 x 100 x 40 mm
- weight: 320 g
- environmental temperature: 23°C ± 5°C
- relative humidity: < 80 %
- accuracy: ± (a% reading + b digit)
- with separate test leads (incl.): TLM72
- Important safety information
Specifications
- display: 6000 counts LCD
- DC voltage: 600 mV / 6 V / 60 V / 600 V / 700 V
- basic accuracy: ± (0.5 % rdg + 2 digits) for 600 mV to 600 V , ± (0.8 % rdg + 2 digits) for 700 V ,
- input impedance: > 10 MOhm
- overload protection: 700 V DC or 700 V AC rms
- AC voltage: 6 V / 60 V / 600 V / 700 V
- basic accuracy: ± (0.8 % rdg + 3 digits) for 6 V to 600 V , ± (1.2 % rdg + 3 digits) 700 V
- input impedance: 10 MOhm
- AC true RMS
- overload protection: 700 V DC or 700 V AC rms
- frequency range: 40 Hz – 2 kHz
- DC current: 0-6 µA / 60 mA / 600 mA / 15 A
- basic accuracy: ± (1.2 % rdg + 2 digits) for 0 to 600 µA and for 6 mA to 600 mA , ± (2.0 % rdg + 3 digits) 15 A
- overload protection: 0.8 A / 700 V fuse in µA mA range; 15 A / 700 V fuse in 15 A range
- AC current: 0-6 mA / 60 mA / 600 mA / 15 A
- basic accuracy: ± (1.5 % rdg + 3 digits) for 0 to 600 mA , ± (2.5 % rdg + 5 digits) for 15 A
- frequency range: 40 Hz – 2 kHz
- overload protection: 0.8 A / 700 V fuse in mA range; 15A / 700 V fuse in 15 A range
- AC true RMS
- resistance: 0-600 Ohm / 6 kOhm / 60 kOhm / 600 kOhm / 6 mOhm / 60 mOhm
- basic accuracy: ± (1.0% rdg + 3 digits) for 0 to 600 Ohm , ± (1.0 % rdg + 2 digits) for 6 kOhm to 6 mOhm , ± (1.5% rdg + 3 digits) for 60 mOhm
- overload protection: 700 V DC or 700 V AC rms
- open circuit voltage: approx. 1 V
- capacitance (auto range): 0-9.999 nF / 99.99 nF / 999.9 nF / 9.999 µF / 99.99 µF / 999.9 µF / 9.999 mF / 99.99 mF
- basic accuracy: ± (3.0 % rdg + 10 digits) for 0 – 9.999 nF , ± (2.5 % rdg + 5 digits) for 99.99 nF, 999.9 nF and 9.999 µF , ± (5.0 % rdg + 10 digits) for 99.99 µF , ± (10.0 % rdg + 20 digits) for 999.9 µF, 9.999 mF and 99.99 mF
- overload protection: 700 V DC or 700 V AC rms
- Frequency (auto range): 0-9.999 Hz / 99.99 Hz / 999.9 Hz / 9.999 kHz / 99.99 kHz / 999.9 kHz / 9.999 MHz
- basic accuracy: ± ( 0.1% rdg + 5 digits)
- sensitivity: sine wave 0.6 V rms (9.999 MHz: 1.5 V rms)
- overload protection: 700 V DC or 700 V AC rms
- temperature:
- °C: -20 °C to 1000 °C
- basic accuracy: ± (3 °C + 1 digit) for -20 0C to 150 °C range , ± (3% rdg + 2 digits) for 151 °C to 1000 °C range
- °F: -4 °F to 1832 °F
- basic accuracy: ± (5 °F + 2 digits) for -4 °F to 302 °F range; ± (3% rdg + 3 digits) for 303 °F to 1832 °F range
- °C: -20 °C to 1000 °C
- diode and audible continuity measurement:
- diode: test forward voltage of diode
- test voltage: approx. 4 V
- continuity: < 50 Ohm built-in buzzer sounds
- test voltage: approx. 2 V
- overload protection: 700 V DC or 700 V AC rms
- diode: test forward voltage of diode
- non contact AC voltage (NCV) detection:
- test voltage range: 90 V ~ 1000 V AC rms
- the buzzer will sound:
- battery test: 1.5 V / 9 V
- basic accuracy: ± (5.0 % rdg + 5 digits)
- rechargeable battery: type 14500 / 3,7 V / 800mAh
- test lead probe : CAT III 1000 V / CAT IV 600 V – 15 A – 18 AWG – LENGTH 75 cm