Log in

Digital clamp meter – CAT III – 600 VAC/VDC – NCV – with data-hold function

Digital clamp meter – CAT III – 600 VAC/VDC – NCV – with data-hold function

111,90

In stock

Digital clamp meter – CAT III – 600 VAC/VDC – NCV – with data-hold function

In stock


SKU: DCM140 This product is a replacement of: APPA30R Check our full Whadda product transition list Category:
Free shipping
Free shipping from €50
EU shipping
EU shipping in 1 to 5 days
Belgian shop
Belgian shop
Return policy
14-day unmodified return policy

Description

This product is a replacement of: APPA30R

Features

  • Safety: The current clamp measures the current without touching the current-carrying conductor (e.g. wire).
  • Easy measurement: During a measurement, there is no need to interrupt the circuit.
  • Non-contact voltage detection: The NCV function allows you to detect the presence of voltage at a safe distance, without making direct contact with the cables.
  • Versatile: The current clamp measures alternating current, voltage, temperature, resistance, diodes and continuity.
  • Automatic and manual range setting.

Specifications

  • Product basic info:
    • Instruction manual languages: Dutch, English, French, German, Polish, Portuguese, Spanish
    • Primary colours: Red
    • Additional colours: Yellow
    • Depth unit: 35 mm
    • Height unit: 194 mm
    • Width unit: 72 mm
    • Weight unit: 230 g
  • Physical properties:
    • Display height: 24 mm
    • Display width: 37 mm
    • LED light: Yes
    • Backlight: Yes
    • Maximum digits display: 3999
  • Electrical data:
    • Capacitance specifications: <ul> <li>10 n/100 n/1 µ/10 µ/100 µ/1 m/10 m/100 mF</li> <li>accuracy: <ul> <li>± (4.0 % of rdg + 25 digits) for 10 nF range</li> <li>± (4.0 % of rdg + 15 digits) for 100 nF – 100 µF range</li> <li>± (5.0 % of rdg + 25 digits) for 1 mF – 100 mF range</li> </ul> </li> <li>overload protection: 15 s max. 250 V (all ranges)</li> </ul>
    • Overload protection: Yes
    • Maximum DC current: 600 A
    • Continuity test: Yes
    • AC current: <ul> <li>40/400/600 A (max. line voltage 240 V)</li> <li>basic accuracy: <ul> <li>± (2.5 % of rdg + 10 digits) for 40 A – 600 A range<br><br></li> </ul> </li> </ul>
    • AC voltage: <ul> <li>0.4/4/40/400/600 V</li> <li>basic accuracy: <ul> <li>± (1.0 % of rdg + 10 digits) for 0.4 V range</li> <li>± (1.0 % of rdg + 5 digits) for 4 V – 400 V range</li> <li>± (1.2 % of rdg + 5 digits) for 600 V range</li> </ul> </li> <li>input impedance: 10 Mohm</li> <li>frequency range: 50 – 1000 Hz</li> <li>maximum input: 600 V<br><br></li> </ul>
    • DC current: <ul> <li>40/400/600 A (max. line voltage 240 V)</li> <li>basic accuracy: <ul> <li>± (2.5 % of rdg + 10 digits) for 40 A ~ 600 A range<br><br></li> </ul> </li> </ul>
    • DC voltage: <ul> <li>0.4/4/40/400/600 V</li> <li>basic accuracy: <ul> <li>± (0.5 % of rdg + 3 digits) for 0.4 V range</li> <li>± (0.8 % of rdg + 5 digits) for 4 V – 400 V range</li> <li>± (1.0 % of rdg + 5 digits) for 600 V range</li> </ul> </li> <li>input impedance: 10 Mohm</li> <li>maximum input: 600 V<br><br></li> </ul>
    • Diode test: Yes
    • Duty cycle: <ul> <li>0.5 – 99 % @ pulse width of 100 µs to 100 ms</li> </ul>
    • Frequency: <ul> <li>10 Hz/100 Hz/1 KHz/10 KHz/100 KHz/1 MHz/10 MHz</li> <li>basic accuracy: <ul> <li>± (0.5 % of rdg + 2 digits) for 10 Hz – 10 MHz range</li> </ul> </li> <li>overload protection: 15 s max. 250 V (all ranges)</li> </ul>
    • True rms: No
    • AC current measurements: 40 A, 400 A, 600 A
    • AC voltage measurements: 4 V, 40 V, 400 mV, 400 V, 600 V
    • Capacity measurements: 1 µF, 1 mF, 10 µF, 10 mF, 10 nF, 100 µF, 100 mF, 100 nF
    • DC current measurements: 40 A, 400 A, 600 A
    • DC voltage measurements: 4 V, 40 V, 400 mV, 400 V, 600 V
    • Frequency measurements: 1 MHz, 10 Hz, 10 kHz, 10 MHz, 100 Hz, 100 kHz, 1000 Hz
    • Duty cycle measurements: 0.5-99 %
    • Resistance measurements: 4 kohm, 4 megohm, 40 kohm, 40 megohm, 400 kohm, 400 ohm
    • Resistance specifications: <ul> <li>400/4 K/40 K/400 K/4 M/ 40 Mohm</li> <li>basic accuracy:<br> <ul> <li>± (1.0 % of rdg + 10 digits) for 400 ohm range</li> <li>± (0.8 % of rdg + 5 digits) for 4 K – 4 Mohm range</li> <li>± (2.0 % of rdg + 10 digits) for 40 Mohm range</li> </ul> </li> <li>overload protection: 15 s max. 250 V (all ranges)</li> </ul>
    • Maximum AC current: 600 A
  • Technical data:
    • Safety standard: EN 61010-1
    • Safety rating: Cat III / 600 V
    • Automatic power-off function: Yes
    • Pollution degree: 2
    • Data-hold function: Yes
  • Set-up options:
    • Alarm sound type: Buzzer
  • Environmental data:
    • Temperature specifications: <ul> <li>-20 °C – 1000 °C</li> <li>basic accuracy:<br> <ul> <li>± (5 % of rdg + 4 °C) for -20 °C to 0 °C range</li> <li>± (2 % of rdg + 3 °C) for 0 °C to 400 °C range</li> <li>± (3 % of rdg + 3 °C) for 400 °C to 1000 °C range</li> </ul> </li> <li>overload protection: 15 s max. 250 V</li> </ul>
  • Power supply:
    • Battery required: Yes
    • Number of batteries: 3
    • Input voltage rating VAC range: 0-600 V
    • Battery operated: Yes
    • Battery voltage rating: 4.5 V
    • Input voltage rating VDC range: 0-600 V
    • Low battery indicator: Yes
    • Battery composition: Alkaline
    • Battery IEC size: AAA (LR03, R03, FR03, HR03, KR03, ZR03 ,24A, 24D, 24LF, UM4, Micro, MN2400, MX2400, MV2400)

Additional information

Weight569 g
Dimensions4,80 × 15,20 × 27,40 cm
Soldering

none

Electronics

none

Coding

none

Mechanics

none

Manuals

Manual

User manual
EN – NL – FR – ES – DE – PL – PT
EN

Downloads

Important safety information EN
DE
ES
FR
NL
Go to Top